TitanTech Polyurethane Floors PXB-730 TITANTECH

Polyurethane Floors PXB-730 TITANTECH

27,20VAT included

Two-component aliphatic polyurethane (polyester) for the protection of interior and exterior floors and pavements with high mechanical resistance.

Size container
Quantity Disponibilidad In stock

You might also like

Related Products ( 3 other products in the same category )

Description

Two-component aliphatic polyurethane (polyester) for the protection of interior and exterior floors and pavements with high mechanical resistance.

Characteristics

- Hard, elastic film with great resistance to wear and impact.

- Exceptional weather resistance and very good color and gloss retention.

- For application on steel and concrete floors, previously primed with epoxy primers, even in chemically aggressive industrial environments, indoors and outdoors.

- For traffic areas of cars, trucks and forklifts, forklifts in warehouses, parking lots, etc.

- Suitable for painting swimming pools.

Certifications

Reaction to Fire UNE EN 13501-1: Bfl-s1/on substrate A2-s1,d0

Abrasion resistance. Method TABER UNE 48250 (28 days of drying at 23ºC)/Abrasive CS10/Weight 1kg/500 and 1000 cycles: loss 25 mg and 59.9 mg

Abrasion resistance. Method TABER UNE 48250 (28 days of drying at 23ºC)/Abrasive CS17/Weight 1kg/500 and 1000 cycles: loss 35.6 mg and 78.5 mg

Surfaces for pedestrian traffic. Determination of slip resistancelying with friction pendulum. Wet test. UNE 41901:2017 EX: Class 1 (19). With fine corundum sown in the first coat (50 g/m2) Class 2 (31). With coarse corundum seeding in the first coat (50 g/m2) Class 2 (37)

Technical data

  • Nature Aliphatic polyurethane (polyester)
  • Semi-gloss Gloss finish (UNE EN ISO 2813) 60º: 50 - 60 GU
  • Density (UNE EN ISO 2811-1) 1, 16 - 1.34 kg/l
  • Yield 6 - 8 m2/l (65 - 90 µ)
  • Drying at 23ºC 60% HR (UNE 48301) 3 - 4 hours
  • Repainting at 23ºC 60% RH (UNE 48283) From 6 pm / Maximum 5 days
  • Base Mix Ratio: 2 / Hardener: 1
  • Pot life at 23ºC 3 - 4 hours
  • Application Methods Brush, roller and airless
  • Airless dilution: 5%
  • Airless Nozzle Diameter: 0.015” - 0.018”
  • Thinner DX810 Epoxy Thinner or DX820 Polyurethane Thinner
  • DX810 Epoxy Solvent Utensil Cleaning
  • Recommended Thickness (UNE EN ISO 2808) 140 - 160 µ (2 coats)
  • Application Conditions, RH<80% +10 ºC - +30 ºC
  • Dyeing Industrial TITANCOLOR System
  • Flash point (UNE EN ISO 3679) Base: 27 ºC / Hardener: 27 ºC
  • Solid Volume (UNE EN ISO 3233-3) 53 - 55 %
  • VOC (UNE EN ISO 11890-2) 490 g/l

Variations in temperature, humidity, thickness, dyeing or depending on the type of support, etc., can cause changes in drying, reperformance or other properties.

How to use

GENERAL RECOMMENDATIONS: Stir well in the container, preferably by mechanical process. Let the mixture rest for 15 minutes before using it to favor the elimination of air. The surfaces to be painted must be clean, dry and consistent. In the painting process, make the splices within 15 minutes. Do not step on until after 24 hours. For transit of light loads, allow a minimum of 48 hours to pass.

Concrete pools: The results of painting the pool are directly related to the preparation of the surface, as well as its construction. The pool must be waterproofed on the outside, with a lining between the pool walls and the surrounding earth.

New concrete pools: After construction, do not paint for at least 2 months. Treat the surface with a mixture of 1 part hydrochloric acid (salfumán) and 3 - 4 parts water. Wash with plenty of fresh water under pressure. Surface preparation with abrasive sandblasting is also possible to roughen the concrete. Allow to dry thoroughly for at least 48 hours and apply a thin coat of SXB 200 Anticorrosive Epoxy Primer with 10% DX 810 Epoxy Solvent; once dry, apply two layers of Poliuretyear Soils PXB 730.

Old unpainted pools: Wash with a mixture of 1 kg of trisodium phosphate with 10 liters of water or with a 5% solution of powdered detergent in water, eliminating mold and grease by rubbing with an esparto brush; rinse with plenty of pressurized fresh water and proceed as in new pools.

Polyester fiber pools: Sand and degrease. Apply 1 coat of SXB 200 Anticorrosive Epoxy Primer. After 18-24 hours, finish with two coats of PXB 730 Polyurethane Floors. In any case, DO NOT fill the pool before 14 days have elapsed from the end of the PUR application. For non-slip finishes, it must be sprinkled to saturation, on the second layer of Polyurethane Floors PXB 730, aggregate of 0.7-0.9 mm. After 24 hours, the remains of non-adhered aggregate will be removed and a final layer of Polyurethane Floors PXB 730 will be finished.

MAINTENANCE OF ALREADY PAINTED SURFACES IN GOOD CONDITION

It is only possible to repaint over two-component schemes. If the schemes applied are of one component, pickling should be carried out and proceed as unprepared surfaces. If the scheme is two-component (Epoxy or polyurethane), thoroughly clean all residues of grease or oil using a pressurized fresh water jet or solvent. It is necessary to roughen the surface to promote adherence. apply handsPolyurethane Floors PXB 730, according to specifications.

MAINTENANCE OF SURFACES ALREADY PAINTED IN POOR CONDITION

In the case of poorly adhered systems, it will be necessary to clean up by scratching. Then patch with the specified Epoxy Primer, preferably by brush. Finish according to selected scheme. If the poorly adhered surface is extensive, proceed as for unprepared surfaces.

8414800429947

TitanTech https://pinturas-dami.com/img/m/479.jpg

22768
8 Items

Data sheet

Kind of product:
Finishing paint or final coat
Degree of Brightness
Semi-shine
Theoretical yield per hand (m2 / L):
5
Number of recommended hands:
two
Sanding between layers
It is not necessary
Dry to Touch at 23ºC and 60% RH
6-12 noon
Time for repainting at 23ºC and 60% RH
Minimum 24 hours, maximum 96 hours
First layer application
Dilute between 10-15% so that it penetrates well into the support
Time for maximum hardness
7 days
Diluent / Cleaning:
Water
Number of Components
2 components
Mix ratio
2 parts of paint per 1 of catalyst
Life of the mixture at 23ºC and 60% RH
2 hours
Type Application:
With brush or roller
Place of application
Interior and Exterior
Paint Wood
Directly
Paint Concrete or Cement
Dilute first hand
Paint Fractated Concrete
Open pore and very dilute first coat
Paint Already Painted Surfaces
Sanding enough to open the pore
Danger for transport: